Home ATTO Products Luminometer Luminescencer NIR

ATTO Products

Luminometer Luminometers
AB-2280 Luminescencer NIR

Tube luminometer
  Luminescencer NIR is the new type of single tube luminometer in photon counting method and wide wavelength range between 350-900nm.

AB-2280 Luminescencer NIR

AB-2280 Luminescencer NIR

Purpose and Application
  • Single,Dual and Triple Reporter assay
  •   Transcriptional factor activity,
  •   Gene expression(Transfection,RNAi,etc)
  • ATP assay
  • Autophagy
  • High-sensitivity Immunoassay
  • Antioxidant activity
Product Summary

Luminescencer NIR(AB-2280) is the new type of single tube luminometer in photon counting method and wide wavelength range between 350-900nm. It has been improved to measure more wide wabelength range which covers near-infrared light (NIR) accurately retaining the high sensitivity and wide dynamic range of conventional luminometer.

Luminescencer NIR can measure target molecules better than conventional luminometers since Near-infrared light can penetrate biological tissues such as skin and blood more efficiently. Besides, a bioluminescent reagents ordnary use as a normal luminometer and it may same level of precision and same sensitivity.

Features
Luminescencer NIR
  • Detector covered for wide wavelength range between 400-900nm→Applicable of bioluminescence & chemiluminescence probes with 650~950nm wavelength which can penetrate the biologicalsubstances (e.g. blood, skin, tissues )
  • Wide dynamic range (8 logs)
  •  High sensitivity→Detection limit is 1zmol(10-21moles) of luciferase molecules
  •  Temperature control system (Room temprature +5°C to 40°C)→Temperature control for appropriate condition to measure living cell and tissue samples
  •  Auto injector system→Programmable injector condition which enable to detect flash-based luminescence.
  • Color separation system→Tricolor of luminescence can be separated and analyzed automatically with filter system (560LP, 600LP). 
Specifications
Product Number AB-2280
Product Name Luminescencer NIR
Sample format φ12×55 mm tubes / 1.5 mL microcentrifuge tubes
Detector Photomultiplier (PMT)
Photon counting methods
Spectral range 350 - 900 nm
Filters F0: no filter, F1: 560nm LP, F2: 600nm LP
Color separation Up to three luminescence colors can be separated with automatic filter change mechanism
Injectors Built-in plunger type (25 - 300 μL) 25 μL steps
Printer Built-in thermal printer 24 digits
Temperature control
(Optional equipment) 
Ambient +5°C - 40°C 
Data saving 200 files of measurement results, 9 files of calibration curve
Exporting and data saving to PC through Windows interface program
Power AC 100-120 or 200-240 V, 50/60Hz, 50 VA
Dimensions 250(W)×310(D)×176(H) mm
Weight  7.5 kg